diff --git a/research/energy/README.md b/research/energy/README.md index e2aadf4..beaf498 100644 --- a/research/energy/README.md +++ b/research/energy/README.md @@ -34,6 +34,10 @@ runs on PV and the grid, so a full battery with ~0 W flow is the normal state. Fronius Symo 3.7 (`192.168.0.143`, Solar API JSON) produced another 4.4 kWh that day. +House meter SDM630 (`electricity.PRAD2`): `total_power_active` is **+ import / − export**, like the +Deye grid registers. Checked 2026-10-23 in InfluxDB: −2.5 to −5.5 kW between 11:00 and 15:00 local +while PV exported, +645 W at night matching Deye's 640 W import. + Considered and rejected (2026-10-23): pointing the logger's second server ("Server B") at our backend. Push frames are poorly documented binary data every ~5 min, need a TCP server with acks, and a wrong setting could cut off the Solarman cloud my father uses. Local FC3 polling