Roadmap
Bottom-up: each milestone builds on a verified one below it, and master stays deployable. Closed milestones shrink to one line here; details stay in git history and in decisions/.
Done
- M0 Foundation ·
v1.0.0:scripts/check.shgate in CI and pre-push, deploy with health check and rollback,/shipand/close-milestone. Baseline (e345063) still does the work: read-only, 8 heat pump values to InfluxDB every 300 s.
Current: M1 Gateway: all readings
Done when: a week on the Pi without manual action, Grafana unchanged. Existing measurements keep their names and fields; new data goes into new measurements (ADR-005). The heat pump stays at 300 s polls while the Frisko app is still in use (MK01 takes one client).
- Skeleton:
Reading, portsDevice,ReadingSink,ModbusClient,ModbusTransport - Modbus core (ADR-007): FC3/FC4 codec, TCP transport, Solarman V5 transport
- Heat pump: legacy
Dom_Pompa.POMPAfields unchanged; 4112–4119, 4201–4203, 4221–4228 and the setpoints intoheat_pump - House meter SDM630 (
electricity.PRAD2) and BME280 via IIO (measurement.MEASUREMENT) - Deye and Fronius into
electricity.deye,electricity.fronius - Influx writer: line protocol over JDK
HttpClient, file buffer (fixes D2, D8) - Poller: one virtual thread per device, snapshot, watchdog without
/healthpolling (D1) - HTTP:
/healthper device,/snapshot - Config file outside the jar (D3), wire
Main, drop modbus4j, influxdb-java and the baseline classes (D4, D5) - Three parts with their images and compose (ADR-010); releases by tag,
update.shon the Pi - On the Pi (2026-10-24): D7, Docker (no iptables, no forwarding),
gateway.json, ufw 8080 onwg0only,v1.1.1running with the heat pump, Deye and Fronius; old service stopped - On the Pi (2026-10-24): IIO overlay, BME280 and the meter in the gateway (
v1.2.1: the meter's converter speaks RTU over TCP);rpi-measurementsstopped and disabled - After the week: remove
rpi-measurementsand the oldhome-pump.servicefiles
Next
| Milestone | Scope | Done when |
|---|---|---|
| M2 Understand the controller | Timing (safe poll rate, response times), which pumps run in which state, open questions in docs/frisko/ |
docs/frisko/ reviewed; F3 limits agreed |
| M3 Backend and web UI, read-only | Backend in Docker in Kraków: history from Influx, snapshot from the gateway; F1, F2, F5, F7 with the schematic and charts after research/ui/; Traefik route, sign-in (ADR-014), on the internet since v2.0.0 (ADR-016). Backend, frontend and their images are on master (ADR-008 proposed, ADR-010); open: REGISTRY_TOKEN, first release, the stack in homelab-compose (Arcane) |
My father sees the heat pump and the energy on his phone |
| M4 Setpoints | F3 through gateway commands with timed restore (ADR-006) and 15 min leases the backend renews (ADR-011), away held until a chosen date (ADR-012); CWU first, then CO; S1–S6. On master and wired, off until commands.enabled (gateway/README.md: Enabling commands): command service with restores, FC6, token-protected /commands, backend /api/setpoints and presets, UI tab Ustawienia |
Father boosts hot water from his phone, value restored on time |
| M4b Battery settings | F8 (ADR-013): Time of Use table and backup reserve from the Bateria view, FC16 with read-back, refused on stale or changed state; on branch/master and off until deyeCommands.enabled (gateway/README.md: Enabling battery commands) |
Father changes the battery program from the app; first live write watched |
| M5 Alarms | F4; decide the channel first (e.g. ntfy, Telegram) | Simulated alarm reaches the phone |
| M6 Native app? | Decide: keep the web UI, WebView wrapper or React Native | Decision recorded |
Known defects in the baseline
- D1 Self-restart works only while something polls
/health(HealthMonitor). - D2 Influx client logs every request (
LogLevel.FULL), ~420 journal lines/hour. - D3 Config is packaged inside the jar.
- D4 Dead code and config:
pollIntervalMs,windowSeconds,ModbusCachedWrapper, write path. - D5 Single and batch reads use different addresses for registers ≥ 4100 (
ModbusRtuTcpRepository). - D6 Development runs wrote test fields into the production
Dom_Pompadatabase. - D8 Each field is written as its own point with its own timestamp, so one poll can split into
points 1 ms apart (
InfluxMetricModbusSender); write one point per poll. - D7 fixed 2026-10-24: Pi
AllowedIPsonly10.0.0.0/24, 10.2.0.0/24, and OPNsense NATs192.168.0.0/24 → 10.0.0.2to its tunnel address, as both sites use192.168.0.0/24.
Knowledge
- Controller: docs/frisko/rx910-se21.md
- Energy devices: research/energy/